Compartilhar o link por e-mail
Nem todos os campos necessários foram preenchidos
enviar email
Bürkert - Perto de você
Escritório /1
  • Sede social
  • Sede
  • Systemhaus
  • Distribuidor
  • Escritório
  • Planta
  • Centro de logística
bürkert
 

Mass Flow Controller / Meter

Tipo 8741 / Nº produto 316187

  • CANopen

Características técnicas

Controller | O2 | 10,00SCCM | 24 V DC | Flange - BürkertFB14 | CANopen

Media / Calibração
Mounting position
vertical, flow downwards
Work area medium 1
10
Unit medium 1
SCCM
Reference medium 1
O2
Special calibration 1
Flow rate < 20 ml
Calibration pressure medium 1 at Qnom
1,9
Units for pressure specifications
bar (ü)
Mensurando
Measuring accuracy from end value
0,30 %
Measuring accuracy of reading
0,80 %
Measuring or control range
1:20
Conexão do Processo Tipo/Tamanho
Port connection 1 DN
FB14
Port connection 1 type
Flange
Port connection 1 standard
Bürkert
Port connection 2 DN
FB14
Port connection 2 type
Flange
Port connection 2 standard
Bürkert
Voltagem / Frequência
Supply voltage
24 V DC
Power consumption according to UL61010-1
4,5 W
Typical electrical power consumption
3 W

Downloads

Ferramentas e vídeos úteis

resistApp - Resistência Química Gráfico

Calculadora Fluid

Informação específica de produto

Digite o número de série indicado na placa de características:

Minha Lista de Comparação