Compartilhar o link por e-mail

Nem todos os campos necessários foram preenchidos
Bürkert - Perto de você
Escritório /1
    • Sede social
      Burkert Brasil Ltda.
      Rua Américo Brasiliense, 2069
      Chacara Santo Antonio
      04715-005 São Paulo - SP
      Brazil
      Telefone +55 11 2186 1155
      Fax +55 11 2186 1165
      E-mail iraqnf@ohexreg.pbz
      Website http://www.burkert.com.br/
  • Sede social
  • Sede
  • Systemhaus
  • Distribuidor
  • Escritório
  • Planta
  • Centro de logística
bürkert
 

    Cabeça de comando para válvulas de processo higiénicas

    Tipo 8681 / Nº produto 339627

    Comparar agora Imprimir
    Produkt-Foto Typ 8681

    The depiction of the products may differ from the actual specific design.

    • Produkt-Foto Typ 8681
    • Produkt-Foto Typ 8681

    Control head type 8681

    • Adaptação universal a válvulas de processo higiénicas
    • Sensor de posição sem contacto com 3 pontos de comutação (função Teach-In)
    • Indicação do estado iluminada a cor
    • Acionamento manual na caixa fechada
    • Interface de comunicação AS-Interface, DeviceNet (opção)

    For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

    Descrição do produto

    A cabeça de comando do tipo 8681 está otimizada para a automatização descentralizada de válvulas de processo higiénicas. Graças à sua adaptação universal, pode ser combinada com todas as tampas, válvulas esféricas, válvulas simples e duplas. No caso de conceitos de automatização descentralizados, a cabeça de comando assume a função de acionamento, transmissão e diagnóstico totalmente pneumáticos até à comunicação bus. A caixa distingue-se pela facilidade de limpeza, proteção IP baseada nas boas práticas e materiais resistentes a químicos para a utilização em instalações de processo higiénicos da indústria farmacêutica, de produtos alimentares e bebidas. Conforme a válvula de processo, podem ser acionadas até 3 câmaras de acionamento pneumáticas independentes entre si. As velocidades de comutação para os dois sentidos do movimento podem ser ajustadas em separado. Uma válvula antirretorno previne erros de comutação condicionados pela pressão de retorno das válvulas de processo. As posições de comutação das válvulas de processo são detetadas pelo sensor de posição indutivo e analógico e comunicadas ao comando hierarquicamente superior. Podem ser ajustados ou calculados automaticamente até 3 pontos de comutação graças à função Teach-In acionada por tecla ou às funções Autotune predefinidas, respetivamente. Além disso, pode ser lida e comunicada uma 4ª posição de comutação por um sensor de aproximação. A indicação do estado iluminada a cor assinala a respetiva posição de comutação da válvula de processo ou as funções de diagnóstico, tais como a necessidade de manutenção ou os estados de erro. As válvulas piloto estão equipadas com uma operação manual mecânica. Com o aparelho fechado, a operação manual patenteada e magneticamente codificada permite a comutação do motor principal.


    Códigos de mercadoria
    90268020
    País
    DE

    Características técnicas

    Nome
    Valor
    Unidade
    Type 8681
    Product sub-group Control head / Position indicator
    Function Control head
    Valve function manual actuation Yes
    Pneumatic pilot valve 1 6144
    Pneumatic pilot valve 2 6144
    Pneumatic function 1 double acting No
    Pneumatic function 1 single acting Yes
    Pneumatic function 2 double acting No
    Pneumatic function 2 single acting Yes
    Valve diameter 4 mm
    Valve 2 diameter 4 mm
    QNn value (gas) 110 l/min
    QNn value 2 (gas) 110 l/min
    Temperature environment min 5 °C
    Temperature environment max 55 °C
    End position feedback internal 3 PCE
    End position feedback external 1 PCE
    End position feedback type Inductive displacement transducer PNP
    End position feedback DC voltage Yes
    End position feedback AC voltage No
    End position feedback top yellow
    End position feedback bottom green
    Displacement transducer type internal linear
    Displacement transducer signal digital
    For Actuator size 40 mm Yes
    For Actuator size 50mm Yes
    For Actuator size 63mm Yes
    For Actuator size 70mm Yes
    For Actuator size 80mm Yes
    For Actuator size 90mm Yes
    For Actuator size 100mm Yes
    For Actuator size 125mm Yes
    For Actuator size 130mm Yes
    For Actuator size 175mm Yes
    For Actuator size 225mm Yes
    Main valve with integrated filter Choke with screw slot
    Port connection 1 type Inner thread
    Port connection 1 thread type G
    Port connection 1 thread marking 1/4
    Port connection 2 type Inner thread
    Port connection 2 thread type G
    Port connection 2 thread marking 1/8
    Port connection 3 type Inner thread
    Port connection 3 thread type G
    Port connection 3 thread marking 1/4
    Electrical connection sort Plug - M12
    Electrical connection type male
    Electrical connection wire length 800 mm
    Electrical connection material Stainless steel
    Voltage / rated voltage 29,5 V
    Voltage / rated voltage 31,6 V
    Supply system-internal No
    Supply via BUS Yes
    Supply via separating barrier No
    AC voltage No
    DC voltage Yes
    Input 1 type digital serial (bus)
    Output 1 type digital Serial (bus)
    Communication interface protocol AS-i
    Control interface DIP switch
    Mounting type 3rd Party actuator
    Protection type (IP max. with suitable connector) IP65/67
    Peso 0,810000 kg
    Tipo de aprovação
    Tipo de certificação
    Exibir tabela completa Recolher tabela

    Downloads

    Folha de dados

    Descrição
    Tam.arquivo
    Idioma / País
    DTS Type 8681 data sheet | control head for automation of hygienic process valves 1,6 MB EN / EU
    DTS Type 8681 data sheet | control head for automation of hygienic process valves [CA units] 3 MB EN / CA
    DTS Type 8681 data sheet | control head for automation of hygienic process valves [US units] 3 MB EN / US
    DTS Type KK01 data sheet | adapterkits for hygienic process valves 5,8 MB EN / EU
    DTS Typ 8681 Datenblatt | Steuerkopf für hygienische Prozessventile 1,6 MB DE / DE
    DTS Typ KK01 Datenblatt | Adaptersets für hygienische Prozessventile 5,8 MB DE / DE
    DTS タイプ8692 データシート |衛生プロセスバルブの アダプタセット 6,7 MB JA / JP

    Manual de instruções

    Descrição
    Tam.arquivo
    Idioma / País
    MAN Additional manual Type 6013 | PX01 - PX03 Use in the explosion-hazard area 125 kB EN,FR,DE / EU
    MAN Additional manual Type 8681 8694 869X 879X | USB Interface for serial communication 2,1 MB EN,FR,DE / EU
    MAN Operating Instructions Software | CANopen Network configuration 362,1 kB EN,FR / EU
    MAN Operating Instructions Type 8681 | Control Head 3 MB EN / EU
    MAN Quickstart Type 8681 | PC service program for control head Type 8681 6,1 MB EN,DE / EU
    MAN Quickstart Type 8681 | Tête de commande 1,6 MB EN,FR,DE / EU
    MAN Service manual Type 8681 | Replacement control head Type 1066 with control head Type 8681 2,9 MB EN,FR,DE / EU
    MAN Software manual | Central configuration management 1,1 MB EN / EU
    MAN Bedienungsanleitung Software | CANopen Netzwerkkonfiguration 364,6 kB DE / DE
    MAN Bedienungsanleitung Typ 8681 | Steuerkopf 3 MB DE / DE
    MAN Manuel de service Type 8681 | Tête de commande 3,1 MB FR / EU
    MAN Manuel du logiciel | Gestion centrale de la configuration 1,1 MB FR / FR
    MAN Software-Anleitung | ZentraleKonfigurationsverwaltung 1,1 MB DE / DE

    Software

    Descrição
    Tam.arquivo
    Idioma / País
    SOW EDS File A.04 52 kB ML
    SOW PC-Programm Typ 8681 2.19 1,5 MB ML

    Declaração UE

    Descrição
    Tam.arquivo
    Idioma / País
    ABD EU-DoC|EU Declaration 2,3 MB EN,FR,DE

    Animação interativa

    Descrição
    Tam.arquivo
    Idioma / País
    3D_ANIMATION 3D-Animation - 8681 3,8 MB DE
    3D_ANIMATION 3D-Animation - 8681 3,8 MB EN

    Folhetos e catálogos

    Descrição
    Tam.arquivo
    Idioma / País
    MISC For hygienic process valves. 267,6 kB EN / EU
    MISC Product Overview Process & Control Valves 3,4 MB BR
    MISC Flyer Best Practice - Fruit syrup production process is sweeter thanks to smart valve control from Bürkert. 447,2 kB EN / GB
    MISC Flyer Best Practice - New control heads in the Fromagerie Bel dairy plant for consistent quality cheese. 352,5 kB EN / GB

    Minha Lista de Comparação